Name Min Max Default Comment Version or Condition
ServoID 0 127 0
NodeID 0 127 0
CAN_BAUDRATE 0 8 0

0=1000 kbps
1=800 kbps
2=750 kbps
3=500 kbps
4=400 kbps
5=250 kbps
6=200 kbps
7=150 kbps
8=125 kbps

UNITNESS_RADIAN_MODE 0 1 0

0=UNITLESS
1=RADIAN

STREAM_TIME(ms) 0 65535 0
STREAM_MODE 0 1 0

0=OFF
1=ON

DEADBAND 0 65535 4

Position error range to Turn off Motor
4096 = 90 deg

INERTIA 0 4095 1

0=off
1=auto
2~4095=manual
( 4095 = 100% )

VOLTAGE_MAX(10mV) 0 65535 0 0 = off
VOLTAGE_MIN(10mV) 0 65535 0 0 = off
TEMPER_MAX('C) 0 65535 0 0 = off
TEMPER_MIN('C) 0 65535 0 0 = off
ECHO 0 65535 0 reset to 0
USER1 0 65535 0 User Value
USER2 0 65535 0 User Value
SPEED_MAX 0 32767 depends on the product
TORQUE_MAX 0 4095 4095

0=0%
4095=100%

OLP_TIME(sec) 0 65535 3 Over Load Protection: Time
OLP_RATE(%) 0 100 100 Over Load Protection: Rate
TIME_UP(ms) 0 65535 0 Time Speed Up: 0% to 100%
TIME_DN(ms) 0 65535 0 Time Speed Down: 100% to 0%
TIME_ES(ms) 0 65535 0 Time Speed Down in Emegency Stop: 100% to 0%
SPEED_VOLTAGE(100mV) 0 65535 depends on the product Voltage that is the reference for actual speed
POSITION_MID 0 16383 8192
POSITION_MIN_LIMIT 0 16383 5462 -60 deg
POSITION_MAX_LIMIT 0 16383 10922 +60 deg
EMG_POS_MAX 0 16383 0
EMG_POS_MIN 0 16383 0
ENABLE_START_POSITION 0 1 0
START_POSITION 0 16383
ENABLE_FAILSAFE_POSITION 0 1 0
FAILSAFE_POSTION 0 16383 0
FAILSAFE_TIME(msec) 0 65535 0
ENABLE BRAKE_INSTEAD_FREE(BLDC) 0 1 0 0=FREE, 1=BRAKE BLDC Only
ENABLE_2PHASE_BRAKE 0 1 0 0=FULL BRAKE, 1=HALF BRAKE BLDC Only
ENABLE_OVERVOLT_BRAKE 0 1 0
BRAKE_VOLT(10mV) 0 65535 0
PRODUCT_NO 0 65535 depends on the product
APP VERSION YYYYMMDDRRV1V2V3

2022030201030900
-> 2022_03_02_01 03-09-00

PARAM VERSION YYYYMMDDRR

2022030201
-> 2022_03_02_01

ZERO_SETUP system, don't care
NodeID(ID2H) don't care
SPEC_POWER 0 - depends on the product 0.01W, 1000 = 10.00W

need current circuit

ENABLE_PEAK_POWER_RATE 0 1 0

need current circuit

PEAK_POWER_RATE 0 2000 0 %%

need current circuit