Difference between revisions of "CanServo/MODE/CAN/en"

From HITEC_HELP
Jump to navigation Jump to search
 
(4 intermediate revisions by the same user not shown)
Line 2: Line 2:


* Register Address: 0x6A
* Register Address: 0x6A
* 0 - CAN 2.0A
* Values:
* 1 - CAN 2.0B
** 0 - CAN 2.0A
* 2 - UAVCAN
** 1 - CAN 2.0B
** 2 - DroneCAN


Actual operation depends a bit on [[CanServo/FW Type]].
Actual operation depends a bit on [[CanServo/FW Type/en]].
* In FW A Type: 0,1,2 can be selected.
* In FW A Type: 0,1,2 can be selected.
* In FW C Type: 0,1 can be selected. Selecting 2 will act as 0 .
* In FW C Type: 0,1 can be selected. Selecting 2 will act as 0 .
Line 16: Line 17:
Communication settings including this setting are applied at the time of servo reset.
Communication settings including this setting are applied at the time of servo reset.
When changing, SAVE and Servo Reset are required.
When changing, SAVE and Servo Reset are required.
* [[CanServo/Save/en]] - SAVE
* [[CanServo/Reset/en]] - Reset

Latest revision as of 01:44, 19 April 2024

Select which protocol to use.

  • Register Address: 0x6A
  • Values:
    • 0 - CAN 2.0A
    • 1 - CAN 2.0B
    • 2 - DroneCAN

Actual operation depends a bit on CanServo/FW Type/en.

  • In FW A Type: 0,1,2 can be selected.
  • In FW C Type: 0,1 can be selected. Selecting 2 will act as 0 .
  • In FW U Type: this setting value is ignored and it operates as 2 unconditionally.
    • The value itself does not change.
    • However, in FW Ver 1.1(2) [ OLD 2.1(2) ], this value is forcibly changed to 2.


Communication settings including this setting are applied at the time of servo reset. When changing, SAVE and Servo Reset are required.