Latest revision as of 08:10, 19 May 2025

Write Command

POS NAME COMMENT
0 'p' Write 2 byte
1 TARGET SERVO ID
2 ADDR LO
3 ADDR HI
4 DATA BYTE 0 (Low)
5 DATA BYTE 1 (High)
POS NAME COMMENT
0 'P' Write 2x2 byte
1 TARGET SERVO ID
2 ADDR 0 LO
3 bit 1:0 = ADDR 0 HI
3 bit 7:2 = ADDR 1 add 64 -> +1~+64
4 DATA 0 BYTE 0 (Low)
5 DATA 0 BYTE 1 (High)
6 DATA 1 BYTE 0 (Low)
7 DATA 1 BYTE 1 (High)
  • NOTE ! NO RETURN PACKET

Read Command

POS NAME COMMENT
0 'g' Read 2 byte
1 TARGET SERVO ID
2 ADDR LO
3 ADDR HI
POS NAME COMMENT
0 'G' Read 2x2 byte
1 TARGET SERVO ID
2 ADDR 0 LO
3 bit 1:0 = ADDR 0 HI
3 bit 7:2 = ADDR 1 add 64 -> +1~+64

Write and Read Command

  • Use 'o' instead of 'p' on Write Command

Return Message

POS NAME COMMENT
0 'y' Return 2 byte
1 SERVO ID
2 ADDR LO
3 ADDR HI
4 DATA BYTE 0 (Low)
5 DATA BYTE 1 (High)
POS NAME COMMENT
0 'Y' Return 2x2 byte
1 SERVO ID
2 ADDR LO
3 bit 1:0 = ADDR 0 HI
3 bit 7:2 = ADDR 1 add 64 -> +1~+64
4 DATA 0 BYTE 0 (Low)
5 DATA 0 BYTE 1 (High)
6 DATA 1 BYTE 0 (Low)
7 DATA 1 BYTE 1 (High)