Difference between revisions of "CanServo/Protocol/Control/en"
		
		
		
		
		
		Jump to navigation
		Jump to search
		
				
		
		
	
 (Created page with "CAN servo is controlled by sending CAN packets with CAN ID set in CanServo/ID2/en and data following the message format below. According to the message type of CAN Data, t...")  | 
				|||
| Line 17: | Line 17: | ||
Old Format:  | V0: Old Format:  | ||
| Line 42: | Line 42: | ||
New Format: (checksum removed)  | V1: New Format: (checksum removed)  | ||
Revision as of 14:27, 18 September 2021
CAN servo is controlled by sending CAN packets with CAN ID set in CanServo/ID2/en and data following the message format below. According to the message type of CAN Data, the register containing servo operation data can be changed or read.
- As a simple example, when the following packet is sent, all received servos change the value of Register 0x30 to 0x1234.
- CAN ID = 0
 - CAN DATA = 'w', 0, 0x30, 0x34, 0x12
 - DLC = 5
 
 
There are 11 types of messages in 8 data bytes of CAN Packet, 3 old types and 8 new types.
The first byte indicates the kind of message.
The second byte is the servo ID.
Here, Target Servo ID must match the value of CanServo/ID1/en of Servo.
Or if 0 is specified, all servos will react.
For the exact procedure, refer to CanServo/Packet Accept Rule/en.
V0: Old Format:
- Old Write Command
- write 1 register
- 0x96, (target servo id), (address), 2, (data low byte), (data high byte), (chksum)
 - DLC = 7
 
 
 - write 1 register
 
- Old Read Command
- read 1 register
- 0x96, (target servo id), (address), 0, (chksum)
 - DLC = 5
 
 
 - read 1 register
 
- Old Return Message
- return 1 register
- 0x69, (servo id), (address), 2, (data low byte), (data high byte), (chksum)
 - DLC = 7
 
 
 - return 1 register
 
- Old message's chksum
- add all bytes before chksum, except first byte
 
 
V1: New Format: (checksum removed)
- Write Command
- write 1 register
- 'w', (target servo id), (address), (data low byte), (data high byte)
 - DLC = 5
 
 - write 2 registers
- 'W', (target servo id), (address 0), (data 0 low byte), (data 0 high byte), (address 1), (data 1 low byte), (data 1 high byte)
 - DLC = 8
 
 
 - write 1 register
 
- Read Command
- read 1 register
- 'r', (target servo id), (address)
 - DLC = 3
 
 - read 2 registers
- 'R', (target servo id), (address 0), (address 1)
 - DLC = 4
 
 
 - read 1 register
 
- Write and Read Command
- write and read: 1 register
- 'x', (target servo id), (address), (data low byte), (data high byte)
 - DLC = 5
 
 - write and read: 2 registers
- 'X', (target servo id), (address 0), (data 0 low byte), (data 0 high byte), (address 1), (data 1 low byte), (data 1 high byte)
 - DLC = 8
 
 
 - write and read: 1 register
 
- Return Message : Servo --> Host
- return 1 register
- 'v', (servo id), (address), (data low byte), (data high byte)
 - DLC = 5
 
 - return 2 registers
- 'V', (servo id), (address 0), (data 0 low byte), (data 0 high byte), (address 1), (data 1 low byte), (data 1 high byte)
 - DLC = 8
 
 
 - return 1 register