Difference between revisions of "CanServo/Register/Return/en"

From HITEC_HELP
Jump to navigation Jump to search
(Created page with "This is a return message of Read Command or a message sent by the servo during stream transmission. * CanServo/MODE/CAN/en = 2.0A, 2.0B ** V0 0x69 message: Data: 0x69, (s...")
 
Line 1: Line 1:
This is a return message of Read Command or a message sent by the servo during stream transmission.
This is a return message of Read Command or a message sent by the servo during stream transmission.


* [[CanServo/MODE/CAN/en]] = 2.0A, 2.0B
* [[CanServo/MODE/CAN/en]] = 2.0A or 2.0B
** V0 0x69 message: Data: 0x69, (servo id), (address), 2, (data low byte), (data high byte), (checksum)
** V0 0x69 message: Data: 0x69, (servo id), (address), 2, (data low byte), (data high byte), (checksum)
*** V0 0x96 Sent when read command is received.
*** V0 0x96 Sent when read command is received.

Revision as of 18:21, 23 September 2021

This is a return message of Read Command or a message sent by the servo during stream transmission.

  • CanServo/MODE/CAN/en = 2.0A or 2.0B
    • V0 0x69 message: Data: 0x69, (servo id), (address), 2, (data low byte), (data high byte), (checksum)
      • V0 0x96 Sent when read command is received.
    • V1 'v' message: Data: 'v', (servo id), (address), (data low byte), (data high byte)
      • Sent when V1 'r' read command is received.
    • V1 'V' message: Data: 'V', (servo id), (address 0), (data 0 low byte), (data 0 high byte), (address 1), (data 1 low byte), data 1 high byte)
      • Sent when V1 'R' read command is received.
      • or when sending a stream.