* Ver 2.0 - testing
* Ver 2.0 - 2023_02_01
** Performance Improvement
** Bug Fixed
*** A bug where the SG10 has a low probability of causing an error situation when first started


* Ver 1.12 - 2022_10_19
* Ver 1.12 - 2022_10_19 -> Ver 2.0 recommanded
** ADD SG10
** ADD SG10



Revision as of 00:23, 7 March 2023

  • Ver 2.0 - 2023_02_01
    • Performance Improvement
    • Bug Fixed
      • A bug where the SG10 has a low probability of causing an error situation when first started
  • Ver 1.12 - 2022_10_19 -> Ver 2.0 recommanded
    • ADD SG10
  • Ver 1.11 - 2022_08_22
    • Add Function
      • Realtime ID1, ID2
        • Reg 0xA2, bit 12 = 0(normal), 1(realtime update)
    • Bug Fixed
      • 0x96 message checksum don't care fixed
  • Ver 1.10 - 2022_05_26
    • Add Function
      • Motor Direction
        • Reg 0x84, bit 0 = 0(normal), 1(reverse), Servo Reset needed
      • Run Mode : CR, Speed
      • DroneCAN
        • Run Mode: Multi-Turn, Servo, CR, Speed
        • DNA
        • Param Service
        • F/W Update
  • Ver 1.7
    • Change Platform from Ver 1.5(2)

  • Ver 1.6(2)

    • Add Function
      • DroneCAN
        • Run Mode: Multi-Turn, Servo
        • DNA (Dynamic Node Alloaction)
    • Relased Date
      • MDxxx - 2022_10_11
      • SG33 - 2022_12_28
  • Ver 1.6(1) (2022_03_22) ---> TEST VERSION ---> Bench Test Only ---> NO FLY !!!
    • Add Function
      • Multi-Turn in DroneCAN
  • Ver 1.6(0) (2021_11_09) ---> TEST VERSION ---> Bench Test Only ---> NO FLY !!! ---> Not recommanded

    • Add Function
      • DroneCAN: DNA
    • found bug
      • (NEW) SERVO_ID may changed by other node's DNA message -> fixed at Ver 1.6(1)

  • Ver 1.5(2) (2021_09_06)

    • Add Function
      • Fail Safe
    • Add Limit
      • Turn off Motor Power, if NOT POSITION_MIN < POSITION_MAX, if Run Mode is SERVO MODE.
    • Bug Fixed
      • The deceleration time of the trapezoidal velocity profile is longer than the specified time.
      • If the Register POWER write message is received without delay, the motor output turns off and does not turn on again before reset.
  • Ver 1.5(1) (2021_06_10)
    • DB961-CAN First Version
    • Add Function
      • Stream CAN ID
    • UAVCAN
      • Now, Node ID and Actuator ID can be set as desired for ID2 and ID1.
        • ID modes ( 1,2,3 ) all removed.
  • Ver 1.5
    • SG50-CAN Second Version
    • Pause Stream function added
    • Bug Fixed
      • Winch bug fixed
  • Ver 1.4(3)
    • DB961-CAN Devel Version
  • Ver 1.4(2)
    • Enhancements
      • Stream Speed Up to 500Hz
      • Setup Hz of Stream Speed
    • Bug Fixed
      • UAVCAN NodeInfo Name first 7 byte dummy removed
    • UAVCAN
      • ID mode 3 added
  • Ver 1.4(1)
    • Enhancements
      • Smart Sense
  • Ver 1.4
    • Add Function
      • High Voltage Electric Brake
      • Start Position ( This is Not Fail Safe )
      • Switch to Bootloader ( Bootloader B3 needed )
      • Edit Register TURN ( CanServo/TURN, CanServo/TURN/en )
    • Bug Fixed
      • work as 640kbps, if setup with 800kbps, 87.5%
    • ADD SG50-CAN
  • Ver 1.3(1)
    • ADD SG33-CAN
  • Ver 1.3
    • Bug Fixed
    • Speed Value: Unit Changed

  • Ver 1.1(2) [ OLD Ver 2.1(2) ]
    • First UAVCAN FW
  • Ver 1.x
    • First FWs