Difference between revisions of "CanServo/Protocol/DroneCAN/ReadWriteRegister/en"
Jump to navigation
Jump to search
Line 6: | Line 6: | ||
NOTE: It is standard for SEQ values to increase from 0 to beyond 31. | NOTE: It is standard for SEQ values to increase from 0 to beyond 31. | ||
NOTE: When setting ID1 and ID2, set Target | NOTE: When setting ID1 and ID2, set Target Actuator ID = 0. | ||
1. Set a Register Value | 1. Set a Register Value |
Latest revision as of 10:14, 17 April 2024
This protocol use custom data format of actuator.ArrayCommand and actuator.Status.
You must set Node ID and Actuator ID. ( CanServo/ID/modes/en )
NOTE: It is standard for SEQ values to increase from 0 to beyond 31.
NOTE: When setting ID1 and ID2, set Target Actuator ID = 0.
1. Set a Register Value
- CAN ID = 8003F200
- CAN DATA = <Actuator ID>, < ADDR of Register >, < DATA LO BYTE >, < DATA HI BYTE >, SEQ
- Actuator ID = 0 (ALL), or 1~127
- ADDR >= 4
ex) 8003F200 07 6A 01 00 C0
- Set value 0x0001 to register 0x6A of Servo 7.
- Target Actuator ID = 7
- Addr = 0x6A
- Data = 0x0001
2. Get a Register Value
- CAN ID = 8003F200
- CAN DATA = 0x80+<Actuator ID>, < ADDR of Register >, 0, 0, SEQ
- Actuator ID = 0 (ALL), or 1~127
- ADDR >= 4
ex) 8003F200 80 0A 00 00 C0
- Get value of register 0x0A from all servo.
- Target Actuator ID = 0 (ALL)
- Addr = 0x0A
3. Return Packet.
- CAN ID = 0803F3xx
- xx = Servo's Node ID
- CAN DATA = <Actuator ID>, < ADDR of Register >, < DATA LO BYTE >, < DATA HI BYTE >
- NOTE: This format is not a DroneCAN standard format.
ex) 0003F307 07 0A 10 00
- Actuator ID = 7
- Addr = 0x0A
- Data = 0x0010
4. SAVE and RESET
- SAVE: Set Value 0xFFFF to Target Servo's Register 0x70.
- SERVO RESET: Set Value 0x0001 to Target Servo's Register 0x46.