Difference between revisions of "CanServo/Protocol/V1.7"

From HITEC_HELP
Jump to navigation Jump to search
Line 2: Line 2:


* Host -> Servo
* Host -> Servo
** ZPST, < set position : -32768 ~ +32767, 16384 = 360 deg >
** ZPST, < set position : -32768 ~ +32767, resolution 16384 = 360 deg >


* Host -> Servo
* Host -> Servo
** ZPGS, <start index : 2 byte>, <N: 2 byte>
** ZPGS, <start index : 2 byte>, <N: 2 byte>
*** 서보는 ZPVS 메시지를 보냅니다.


* Servo -> Host
* Servo -> Host
** ZPVS, <start index : 2 byte>, <N: 2 byte>, <Pi : setted position>, <Vi : position sensor value>, ...
** ZPVS, <start index : 2 byte>, <N: 2 byte>, <Pi : setted position>, <Vi : position sensor value>, ...
*** 주의: 서보는 전송 버퍼 등의 한계를 확인하여 최대 N개의 데이터를 보냅니다.

Revision as of 03:23, 24 September 2025

Pot Calibration

  • Host -> Servo
    • ZPST, < set position : -32768 ~ +32767, resolution 16384 = 360 deg >
  • Host -> Servo
    • ZPGS, <start index : 2 byte>, <N: 2 byte>
      • 서보는 ZPVS 메시지를 보냅니다.
  • Servo -> Host
    • ZPVS, <start index : 2 byte>, <N: 2 byte>, <Pi : setted position>, <Vi : position sensor value>, ...