Select which protocol to use.

  • Register Address: 0x6A
  • Values:
    • 0 - CAN 2.0A
    • 1 - CAN 2.0B
    • 2 - UAVCAN

Actual operation depends a bit on CanServo/FW Type/en.

  • In FW A Type: 0,1,2 can be selected.
  • In FW C Type: 0,1 can be selected. Selecting 2 will act as 0 .
  • In FW U Type: this setting value is ignored and it operates as 2 unconditionally.
    • The value itself does not change.
    • However, in FW Ver 1.1(2) [ OLD 2.1(2) ], this value is forcibly changed to 2.