HLS12

  • The HLS12-CAN actuator incorporates the specific characteristics of the HLS12 model within CAN servo firmware version 2.3.
  • For all other details, please refer to the specifications for firmware version 2.3.

Operating range

  • For example, with a 100 mm product, the innermost point corresponds to the 0 mm position, and the outermost point corresponds to the 100 mm position.
  • It operates corresponding to the -60° and +60° positions of POSITION_NEW.
  • POSITION_NEW (Reg 30)
    • min = -60 deg = 8192 - 60 x 16384 / 360
    • max = +60 deg = 8192 + 60 x 16384 / 360

Coordinate system

  • POSITION_NEW (Reg 30) = Target Location = -60 deg to +60 deg
  • REAL POSITION_NEW (Reg 37) = The value of POSITION_NEW converted into an actual distance value.
  • VIRTUAL POSITION_NEW (Reg 35) = A virtual target that moves toward POSITION_NEW based on the speed setting
  • POSITION (Reg 12) = Current position = Same coordinate system as POSITION_NEW
  • REAL POSITION (Reg 13) = POSITION value converted into distance units
    • ex) 1500 = 15.00 mm
  • The distance unit changes if the product length exceeds 200 mm.
    • ex) 1500 = 150.0 mm

Power Rate

  • It adjusts the output at a specified ratio without the need to modify the power (wattage) setting.
  • Reg 0x29
    • 4095 = 100%
  • Condition
    • Reg 0x41 활성화 필요, bit 13 = 1

Changed Unit

  • Velocity Max
    • 1 = 0.01 mm / sec
  • option/deadband
    • 1 = 0.01 mm

Acceleration and deceleration

  • Adjust the smoothness of acceleration and deceleration using the Smart Sense setting value.
  • Values ​​of 0, 1, and 4095 result in no acceleration or deceleration smoothing.
  • The range is from 4095 down to 2; values ​​closer to 2 result in smoother acceleration and deceleration.
    • Note: If the value is very low, the time required to reach the target may become significantly longer.
  • Recommended range: 500 – 3000

Calibration Data

  • The physical operating limits are defined in POSITION MIN/MID/MAX.
  • Do not modify these values.

기타

  • CAN Sample Point 50%, 87.5% 선택 가능
  • HW_DEF_1(Reg 0xA5) = HLS12 길이 = mm 단위 = 30, 50, 100
  • HW_DEF_2(Reg 0xA7) = HLS12 기어비 = 1:x = 50, 100, 210, 380