Custom CAN / CAN-FD baudrate

  • if CLK is 0, parameter not valid.
  • if fEnable is 1 on boot, servo try Custom Baudrate.
  • if fReturn is 1 on boot, servo will wait for "Confirm Custom CAN" message for 'WaitTime' seconds.

Get Clock List

  • Host -> Servo
    • Get Clock List
      • ZcGL, ID1(1), ID2(4)
  • Servo -> Host
    • Return Clock List
      • ZrRL, ID1(1), ID2(4), N(1), ClockList(n)

Setup Custom Parameters

  • Host -> Servo
    • Set Custom CAN parameters
      • ZcSP, ID1(1), ID2(4), CLK(1), Npre(1), NQ1(1), NQ2(1), Dpre(1), DQ1(1), DQ2(1), WaitTime(2), fEnable(1), fReturn(1)
      • Servo: Check CLK with Clock List
      • Servo: Auto Send: "Return Custom CAN parameters" message
    • Set fEanble of Custom CAN parameters
      • ZcSE, ID1(1), ID2(4), fEnable(1)
    • Get Custom CAN parameters
      • ZcGP, ID1(1), ID2(4)
  • Servo -> Host
    • Return Custom CAN parameters
      • ZrRP, ID1(1), ID2(4), CLK(1), Npre(1), NQ1(1), NQ2(1), Dpre(1), DQ1(1), DQ2(1), WaitTime(2), fEnable(1), fReturn(1)


  • NOTE
    • WaitTime = mili seconds

Confirm Custom Parameters

  • Servo Wait on boot, if fEnable=1 and fReturn=1
    • WaitTime 설정동안, Confirm 메시지를 기다림.
    • 시간 경과시 fEanble=0, fReturn=0 으로 변경하고 Reset
  • Host -> Servo
    • Confirm Custom CAN
      • ZcCP, ID1(1), ID2(4)
      • Servo:
        • Step 1: Auto Send: "Return of Confirm Custom CAN" message
        • Step 2: Change fReturn 1 to 0
  • Servo -> Host
    • Return of Confirm Custom CAN
      • ZrRC, ID1(1), ID2(4), fReturn(1)